Risk of fire and explosion
AWOripe gas contains 5% ethylene gas, which is highly flammable and forms a flammable mixture with air. Although the high nitrogen content dilutes the mixture and reduces the risk of fire, the presence of ethylene makes the gas flammable. The ethylene mixture can be ignited by low energy sources such as static electricity, sparks or hot surfaces, especially in confined spaces or under pressure.
In the event of a fire, the flow of gas should be cut off immediately, as this is the most effective way to extinguish the fire. Other methods of extinguishing the fire may be dangerous, as a leaking ethylene mixture may re-ignite and form an explosive gas cloud. To prevent the fire from spreading, the surrounding area can be cooled with water if this can be done safely.
Risk of suffocation
An increase in the hydrogen concentration in the breathing air presents a choking hazard. Asphyxiation will occur unnoticed and may result in death.
First aid
The person suffering from oxygen deficiency must be immediately moved to fresh air. If the victim is having difficulty breathing or is not breathing, administer artificial respiration as quickly as possible and call for help. When rescuing a victim, it is important to remember not to enter an oxygen-deprived area without breathing equipment.
Access
- When handling the substance, follow the instructions and safe working practices given
- The gas handler must be properly trained
- Use only carefully checked pressure regulators and other operating equipment suitable for this gas. If in doubt, contact Woikoski.
- Open the valve slowly to avoid pressure shock
- The valve is opened and closed by hand. The use of assistive devices is prohibited!
- It takes about one turn to open the bottle.
- The cylinder in use must be properly secured.
- Keep the valve outlets clean!
- Close the cylinder valve after each use and when the cylinder is empty.
- Always report damaged valves and cylinders to Woikoski.
- The driver must be aware of the potential dangers of the load and know his duties in the event of accidents and incidents.
- Cylinders should be transported in an upright position
- The load must be secured
- Cylinders must not be knocked, thrown or dropped from the truck platform
- Attention to ADR regulations during transport
- Observe all legal and local requirements for the storage of cylinders
- Store cylinders in a well ventilated area
- Cylinders should not be stored in conditions that promote corrosion
- Cylinders are stored upright and secured so that they cannot fall over
- Valve guards must be in place AT ALL TIMES
- Empty and full cylinders to be kept separate